General Specifications

Standards and codes

The building is designed in accordance with the following codes and standards: NCC: 2022 AS/NZS 1170.1:2002 AS/NZS 1170.2:2021 AS/NZS 1170.3:2003 AS/NZS 1170.4:2007 AS 2870:2011 AS 3600:2018 AS 4100:2020 AS/NZS 4600:2018

Design criteria

Unless otherwise stated, this building is suitable for the site wind classification of up to N3 for non cyclonic and C2 for cyclonic. No allowance has been made for earthquake or snow loading. It is the responsibility of the purchaser to ensure that this classification is suitable for the site and proposed building use. This should be obtained from a suitably qualified and insured person/company.

Dimensions

All dimensions nominated are nominal sizes only.

Drawing for Council Submission

Full set of plans for submission to council including engineering approval. Site specific drawings are not provided, eg site plan, drainage plan etc. Site specific reports are also not provided, eg bush fire protection plan, energy efficiency report.

Environmental characteristics

All components of the steel building are designed to suit the conditions generally described as “non-aggressive”. Care must be taken with any steel building to ensure that regular maintenance is carried out. The suitable conditions and maintenance requirements are defined in the various BlueScope Steel Technical Bulletins.

Roof and wall sheeting

Roof sheeting is supplied in Corodek. Wall sheeting is supplied in Corodek and fixed horizontally. 

Fasteners

All connections are tek screwed. Roof and wall screws provided to Climaseal® 4 standard. All other screws class 3.

Slab

Designs provided for Class A, S, M or H1 soil conditions with a safe bearing value >100kPa.

Gutters

The gutter type supplied will be nominated by our supplier as the most common type for your area.

Marking, cutting and drilling

Most components are marked for easy identification and placement and are cut to length. It will be necessary to cut and/or drill some components on site.

Colours

Certain products and areas have a limited colour range. Please consult your representative for more information regarding available colours in your area.

Down Pipes

Down pipes are to be provided by others to suit your roof and water tank requirements.

Windows and doors

Window and door locations are nominated on the plans. The supply of windows and doors are not included in the quoted price. To avoid on-site damage, these are best purchased locally when required. All door frames are designed for 2.4m high doors.

Delivery

Delivery is quoted for standard delivery routes. Additional fees apply where the address is beyond the normal route. Alternately, delivery can be organised by the customer ex-works.

Ex Works

 Collection of your steel kit home will be from our suppliers depots within your nominated city.